NetEngine 8000 M1C, Router 16*10GE + 12*GE, 2*AC Power | Huawei

HUA-NE-8000-M1C-AC

Nuevo

NetEngine 8000 M1C Basic Configuration (Includes M1C Chassis, Fixed Interface(16*10GE + 12*GE),2*AC Power,without Software and Document)

                                                               

Referencia: HUA-NE-8000-M1C-AC

Más detalles

Ficha técnica

Redes y conexiones inalámbricasRouter

Más información

NetEngine 8000 M1C, Router 16*10GE + 12*GE), 2*AC Power  | Huawei

Los routers de la serie NetEngine 8000 de Huawei están diseñados para la era del 5G y de la nube. Proporcionan una capacidad ultra grande y varias interfaces para satisfacer los requisitos de los clientes de acceso multiservicio, de gran capacidad y de alta densidad.

*Solicite cotización a tecnico@anvimur.com

Descripción Hardware NetEngine 8000 M1C, aquí.

Más información Huawei NetEngine 8000 M1C, aquí.

Especificaciones

ItemSpecification
Cabinet installation standardsETSI (21-inch); IEC (19-inch); IMB (3U)
Dimensions without packaging (H x W x D) [mm(in.)]44.5 mm x 442 mm x 220 mm (1.75 in. x 17.4 in. x 8.66 in.)
Dimensions with packaging (H x W x D) [mm(in.)]255 mm x 585 mm x 390 mm (10.04 in. x 23.03 in. x 15.35 in.)
Chassis height [U]1 U
Weight without packaging [kg(lb)]3.9 kg (8.60 lb)
Weight with packaging [kg(lb)]6.1 kg (13.45 lb)
Typical power consumption (with configuration) [W]89.21 W
Typical heat dissipation (with configuration) [BTU/hour]289.43 BTU/hour
MTBF [year]45.43 year
MTTR [hour]2 hour
Availability0.99999
CPU8-core 1.5GHz
SDRAM4 GB
Flash memory64 MB
Storage8 GB
Power supply modeAC
Rated input voltage [V]200 V to 240 V/100 V to 127 V dual live wires, support 240V HVDC
Input voltage range [V]100 V to 240 V
Maximum input current [A]4 A
Maximum input cable size [mm²]Standard C13 cable
Front-end circuit breaker/fuse [A]≥2A
Heat dissipation modeAir cooling
Airflow directionFrom left to right
Noise at normal temperature (acoustic power) [dB(A)]55 dB(A)
Switching capacity344G bit/s(Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed.
Redundant power supply1+1
Redundant fansIf a single fan fails, the system can still work for a short period of time at an ambient temperature of 50°C (122°F).
Long-term operating temperature [°C(°F)]-40°C to 65°C (-40°F to 149°F)
Restriction on the operating temperature variation rate [°C(°F)]≤ 30°C/hour (54°F/hour)
Storage temperature [°C(°F)]-40°C to 70°C (-40°F to 158 °F)
Long-term operating relative humidity [RH]5% to 95% RH, non-condensing
Storage relative humidity [RH]5% to 100% RH, non-condensing
Long-term operating altitude [m(ft.)]≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].)
Storage altitude [m(ft.)]< 5000 m (16404 ft.)

Material relacionado