HUA-NE-8000-M1C-AC
New product
NetEngine 8000 M1C Basic Configuration (Includes M1C Chassis, Fixed Interface(16*10GE + 12*GE),2*AC Power,without Software and Document)
HUA-NE-8000-M1C-AC
This product is no longer in stock
Warning: Last items in stock!
Availability date:
| Networking and Wireless | Router |
Huawei NetEngine 8000 series routers are designed for the 5G and cloud era. They provide ultra-large capacity and various interfaces to meet customers' requirements for multi-service, large-capacity, and high-density access.
| Item | Specification |
| Cabinet installation standards | ETSI (21-inch); IEC (19-inch); IMB (3U) |
| Dimensions without packaging (H x W x D) [mm(in.)] | 44.5 mm x 442 mm x 220 mm (1.75 in. x 17.4 in. x 8.66 in.) |
| Dimensions with packaging (H x W x D) [mm(in.)] | 255 mm x 585 mm x 390 mm (10.04 in. x 23.03 in. x 15.35 in.) |
| Chassis height [U] | 1 U |
| Weight without packaging [kg(lb)] | 3.9 kg (8.60 lb) |
| Weight with packaging [kg(lb)] | 6.1 kg (13.45 lb) |
| Typical power consumption (with configuration) [W] | 89.21 W |
| Typical heat dissipation (with configuration) [BTU/hour] | 289.43 BTU/hour |
| MTBF [year] | 45.43 year |
| MTTR [hour] | 2 hour |
| Availability | 0.99999 |
| CPU | 8-core 1.5GHz |
| SDRAM | 4 GB |
| Flash memory | 64 MB |
| Storage | 8 GB |
| Power supply mode | AC |
| Rated input voltage [V] | 200 V to 240 V/100 V to 127 V dual live wires, support 240V HVDC |
| Input voltage range [V] | 100 V to 240 V |
| Maximum input current [A] | 4 A |
| Maximum input cable size [mm²] | Standard C13 cable |
| Front-end circuit breaker/fuse [A] | ≥2A |
| Heat dissipation mode | Air cooling |
| Airflow direction | From left to right |
| Noise at normal temperature (acoustic power) [dB(A)] | 55 dB(A) |
| Switching capacity | 344G bit/s(Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed. |
| Redundant power supply | 1+1 |
| Redundant fans | If a single fan fails, the system can still work for a short period of time at an ambient temperature of 50°C (122°F). |
| Long-term operating temperature [°C(°F)] | -40°C to 65°C (-40°F to 149°F) |
| Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (54°F/hour) |
| Storage temperature [°C(°F)] | -40°C to 70°C (-40°F to 158 °F) |
| Long-term operating relative humidity [RH] | 5% to 95% RH, non-condensing |
| Storage relative humidity [RH] | 5% to 100% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
| Storage altitude [m(ft.)] | < 5000 m (16404 ft.) |