CE6863E-48S6CQ switch (48*25GE SFP28, 6*100GE QSFP28, 2*AC power modules, 4*fan modules, port-side intake).

HUA-CE6863E-48S6CQ

More details

Add to wishlist

Data sheet

Networking and WirelessSwitch

More info

CE6863E-48S6CQ, 48*25GE SFP28, 6*100GE QSFP28, 2*AC | Huawei

Offering high-performance, high port density, and low latency, CloudEngine 6800 series switches enable enterprises and carriers alike to build cloud-oriented data center networks. The series features an advanced hardware design combined with either 10 GE, 25 GE, or 50 GE access ports, and 40 GE, 100 GE, or 200 GE uplink ports. Advanced data center features, high-performance stacking technologies, and flexible airflow capabilities complete the series. CloudEngine 6800 is well-suited to both the core and aggregation layers, and is fully compatible with CloudEngine 16800 and 12800 series switches, enabling enterprises to build scalable, simplified, open, and secure networks.

Professional Managed Switch Series for operators and integrators, 10 Gigabit Series.

Ideal for professional installations for CPDs centres, hospitality environments, access point management.
They are intended for mass flow traffic environments requiring professional management.
* Including all standard software licenses.

Hardware description CE6863E-48S6CQ, here.

More information Huawei CE6863E-48S6CQ, here.

ItemSpecification
Dimensions with packaging (H x W x D) [mm (in.)]175 mm x 650 mm x 550 mm (6.9 in. x 25.6 in. x 21.7 in.)
Dimensions without packaging (H x W x D) [mm (in.)]Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.1 mm (1.72 in. x 17.40 in. x 17.56 in.)
Weight without packaging (base configuration) [kg (lb)]5.7 kg (excluding optical modules, power modules, and fan modules)
Weight without packaging (full configuration) [kg (lb)]7.8 kg (17.2 lb) (including AC power modules and fan modules, excluding optical modules, calculated based on the heaviest model if multiple models are supported)
Installation TypeCabinet Installation
CPU4-core, 1.4GHZ
MemoryDRAM: 4 GB
NOR Flash64 MB
NAND Flash4 GB
USBSupported
Power supply modeAC
DC
HVDC
Console portRJ45
Downlink Service interface48*25GE SFP28 (Note: 1. 25GE ports can be configured to work at 10 Gbit/s or 1 Gbit/s. Every four downlink 25GE ports form a group, and can be configured to work at 10 Gbit/s or 1 Gbit/s through the command; 2. 10GE LRM/80KM linear optical modules are not supported; 3. 1 m 25GE copper cables and 1 m/3 m/5 m 10GE copper cables are supported, and auto-negotiation of copper cables is not supported; 4. 25GE copper cables can only be used on stack ports and M-LAG peer-link ports.)
Uplink Service interface6*100GE QSFP28 (Note: 1. Each 100G QSFP28 port can be configured to work at 40 Gbit/s. 2. A 100G QSFP28 port cannot be split into four 25GE or 10GE ports. 3. 100GE and 40GE 1/3/5 m copper cables are supported, but auto-negotiation of copper cables is not supported. 100GE and 40GE copper cables can only be used on stack interfaces and M-LAG peer-link interfaces. 100G 3/5 m copper cables support only RS FEC. After the non-RS FEC mode is configured, the port enters the error-down state.)
Service port supporting the stack function25GE optical ports, and 100GE optical ports
RTCSupported
Typical power consumption [W]226 W (100% throughput, SFP28 high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules)
261 W (100% throughput, short-distance optical modules on all ports, dual power modules)
Typical heat dissipation [BTU/hour]771 BTU/hr (100% throughput, SFP28 high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules)
891 BTU/hr (100% throughput, short-distance optical modules on all ports, dual power modules)
Static power consumption [W]167 W
Static heat dissipation [BTU/hour]570 BTU/hour
Maximum power consumption [W]384 W
Maximum heat dissipation1310
Number of power modules2
Redundant power supply1+1 backup
Rated input voltage [V]600 W AC&240 V DC power module: 100 V AC to 240 V AC, 50/60 Hz; 240 V DC
1000 W DC power module: –48 V DC to –60 V DC
1200 W high-voltage DC power module: 240 V DC to 380 V DC
Input voltage range [V]600 W AC&240 V DC power module: 90 V AC to 290 V AC, 45 Hz to 65 Hz; 190 V DC to 290 V DC
1000 W DC power module: –38.4 V DC to –72 V DC
1200 W high-voltage DC power module: 190 V DC to 400 V DC
Maximum input current [A]600 W AC&240 V DC power module: 8 A (100 V AC to 240 V DC); 4 A (240 V DC)
1000 W DC power module: 30 A (–48 V DC to –60 V DC)
1200 W high-voltage DC power module: 8 A
Rated output power [W]600 W AC&240 V DC power module: 600 W
1000 W DC power module: 1000 W
1200 W high-voltage DC power module: 1200 W
Certification· Complies with safety standards.
· Complies with EMC standards.
· Complies with environmental protection standards.
Power supply surge protection [kV]AC: 6 kV in common mode and 6 kV in differential mode
DC: 4 kV in common mode and 2 kV in differential mode
HVDC: 4 kV in common mode and 2 kV in differential mode
Types of fansPluggable
Number of fans4
Redundant fansThe device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Heat dissipation modeAir cooling
Airflow directionFront-to-back or back-to-front, depending on the fan modules and power modules.
Availability0.9999962836
MTBF [year]47.81 year
MTTR [hour]1.95 hour
Noise at normal temperature (27°C, sound pressure) [dB(A)]Front-to-back airflow: < 58 dB(A)
Back-to-front airflow: < 57 dB(A)
Noise at high temperature (40°C, sound pressure) [dB(A)]Front-to-back airflow: < 75 dB(A)
Back-to-front airflow: < 74 dB(A)
Long-term operating altitude [m (ft.)]≤ 5000 m (16404 ft.)
Long-term operating relative humidity [RH]5% RH to 95% RH, noncondensing
Long-term operating temperature [°C (°F)]0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.)
NOTE:
When the altitude is 1800–5000 m (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Storage temperature [°C (°F)]-40°C to +70°C (-40°F to +158°F)

Accessories